Products
REF 470
TRACOE vario extract Tracheostomy Tube with Low Pressure Cuff, Suction Line and Adjustable Neck Flange
« backforward »In sterile package
order-no.: REF 470
-
Cannula with 15 mm connector, cuff, X-ray contrast line, scale and fixture for subglottic suction
-
2 connectors for suction pumps
- Obturator and wide neck strap
TRACOE vario Colour Coding
REF-numbers are marked according to the TRACOE vario colour coding. The colour coding is conspicuously printed on each box. This helps you organise your inventory and quickly and reliably locate the right tube.
Accessory for TRACOE vario Tubes
- Speaking valves and HMEs
see TRACOE care - REF 517, Seldinger Guide Wire with Guiding Catheter and
REF 518, Seldinger Guide Wire
see TRACOE percutan
Each tube is supplied with
an obturator and wide neck strap.
Straps are also available separately (REF 903-F).

TRACOE vario extract: Advantages and Special Information
- Accumulated subglottic secretions can be suctioned off at the lowest point, in other words right above the cuff. This reduces the risk of bacterially contaminated secretions entering the lower respiratory tract and the risk of developing aspiration pneumonia.
- The suction channel is integrated in the wall of the tube so it will not exert any pressure. This prevents pressure necroses in the tracheostoma.
- The suction channel has an opening above the cuff, and is connected at the machine end to a suction tube. Via this tube, secretions can be suctioned off either intermittently with the aid of a syringe (Luer connector) or using one of the included connectors fitting with a suction pump.
- The variably adjustable neck flange with rotating wings permits universal adjustment to any neck anatomy (e.g. swollen necks, postoperative edema, asymmetrical necks).
technical data TRACOE vario extract Tracheostomy Tube with Low Pressure Cuff, Suction Line and Adjustable Neck Flange**
| Size | ID | AD | Länge A | Länge C | Länge B | TL | AB | FV | MD | BW | REF-No. |
|---|---|---|---|---|---|---|---|---|---|---|---|
| mm | mm | mm | mm | mm | mm | mm | ml | mm | ø° | ||
| 07 | 7,0 | 9,7 | 33 | 32 | 15 | 80 | 86 | - | 23 | 100 | REF 470-07 |
| 08 | 8,0 | 11,2 | 35 | 35 | 20 | 90 | 97 | - | 26 | 100 | REF 470-08 |
| 09 | 9,0 | 12,3 | 38 | 35 | 27 | 100 | 106 | - | 30 | 100 | REF 470-09 |
| 10 | 10,0 | 13,7 | 38 | 37 | 35 | 110 | 120 | - | 32 | 100 | REF 470-10 |
|
ID: inside diameter (clear width) at bottom of cannula AD: outside diameter at bottom of cannula TL: length along centre line AB: length along outer bend FV: filling volume of cuff (REF 450 and REF 460) MD: cuff diameter (REF 450 and REF 460) BW: bending angle
To order, specify REF + size, e.g. REF 450-06
|
|||||||||||
technical Overview
* Images may differ from original.
** Technical modifications and errors excepted.
download catalogue
TRACOE medical GmbH
Reichsforststr 32
60528 Frankfurt/Main
Phone: +49 (0)69 - 665 668-0
Fax: +49 (0)69 - 665 668-10
E-Mail: info@tracoe.com